specification : 1/2\,1\,3/4\
thread type : g
Desciption :
Temperature setting range: 40-45?
Hot and Cold water inlet temperature range: 4-95?
Maximum working temperature:=99 ºC
Temperature stability:+/-2 ºC
Working pressure:0.03-1Mpa
Ideal working pressure:01-0.5Mpa
Three way valves:Two outlets , one inlet
1. Technical Data
G1/2”
a. Maximum working temperature: 99?
b. Rated outlet flow on 1 bar pressure drop:11.67L/Min
other size that the flow rate is different.
2. Materials of Construction
a. Valve body: Nickel plated brass
b. Shutter: PPO
c. Connection: Inlets-Male thread, outlet-Male thread
3. Usage of Selector valves
Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.
4.How they work ?
Temperature range: 40---45?
it will flow out from cold port When coming water temperatureis below 40?, It will flow out from hot port When coming water temperature above 45? . it will flow out from both ports When the water temperature between 40? and 45?,.
Normally it is applied in solar heater and gas/electric water heater system. When sun shine is short and water temp from solar geyser is not hot enough, the water will be flow into for the secondary heating, such as gas or electric heater for second heating.
For detailed information, please see the below picture: